{"id":5021,"date":"2026-11-06T08:03:38","date_gmt":"2026-11-06T08:03:38","guid":{"rendered":"https:\/\/www.tyeefire.com\/?p=5021"},"modified":"2026-11-27T08:09:43","modified_gmt":"2026-11-27T08:09:43","slug":"smoke-detector-for-small-business-placement-wiring-and-false-alarm-reduction-for-distributors","status":"publish","type":"post","link":"https:\/\/www.tyeefire.com\/de\/smoke-detector-for-small-business-placement-wiring-and-false-alarm-reduction-for-distributors\/","title":{"rendered":"Smoke Detector for Small Business: Placement, Wiring and False-Alarm Reduction for Distributors"},"content":{"rendered":"<p data-pm-slice=\"0 0 []\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-5022\" src=\"https:\/\/www.tyeefire.com\/wp-content\/uploads\/2026\/11\/image_1795411691-zr3xp5y8.webp\" alt=\"\" width=\"1536\" height=\"1024\" srcset=\"https:\/\/www.tyeefire.com\/wp-content\/uploads\/2026\/11\/image_1795411691-zr3xp5y8.webp 1536w, https:\/\/www.tyeefire.com\/wp-content\/uploads\/2026\/11\/image_1795411691-zr3xp5y8-300x200.webp 300w, https:\/\/www.tyeefire.com\/wp-content\/uploads\/2026\/11\/image_1795411691-zr3xp5y8-1024x683.webp 1024w, https:\/\/www.tyeefire.com\/wp-content\/uploads\/2026\/11\/image_1795411691-zr3xp5y8-768x512.webp 768w, https:\/\/www.tyeefire.com\/wp-content\/uploads\/2026\/11\/image_1795411691-zr3xp5y8-18x12.webp 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/p>\n<p data-pm-slice=\"0 0 []\">A cheap smoke detector is not what prevents trouble in a small business. Problems come from unsuitable placement, from environmental conditions the device was never suited to, or from repeated nuisance alarms \u2014 the kind that eventually lead someone to take the battery out. Paying more for the unit does not fix any of those. Price is the easiest thing to compare on a quotation sheet and the least useful thing to compare on site. One terminology point before going further, because the two terms carry different code provisions: a <em>smoke alarm<\/em> is a self-contained unit with sensor, sounder and power source in one housing, while a <em>smoke detector<\/em> is a sensor connected to a control panel or system.<\/p>\n<p>For distributors, that changes what a good recommendation looks like. A distributor who sells on unit price alone is competing on the one variable the customer can check without help. A distributor who can walk a shop floor, a back office, a stockroom and a small kitchen and say where detection belongs \u2014 and where it does not \u2014 is selling something the customer cannot easily source elsewhere. The guide follows the order a site visit usually takes, so you can apply it to a real premises rather than to a list of product features.<\/p>\n<p>One scope note. Requirements vary by jurisdiction and by the edition of the model code your authority having jurisdiction (AHJ) has adopted, and the adopted edition and any local amendments always govern the final layout.<\/p>\n<h2 id=\"42ca9835-01b9-47a6-be06-db1ae9fb1b90\" data-toc-id=\"42ca9835-01b9-47a6-be06-db1ae9fb1b90\">Placement by Space: Ceiling Height, Kitchen and Dusty Areas<\/h2>\n<p>Before detector type is even discussed, three things should be established: ceiling height, ceiling construction, and the environmental conditions of the space. They are key initial considerations, not the only ones \u2014 the building&#8217;s use, the applicable code, the detector&#8217;s listing and the fire strategy for the premises can all affect placement too. Get these three right, though, and most nuisance-alarm problems never start.<\/p>\n<p><strong>Ceiling height and ceiling shape.<\/strong> A common NFPA-based reference for a flat, smooth ceiling is listed spacing of about 30 ft for spot smoke, with the maximum distance from any point on the ceiling to the nearest detector at 0.7 times that spacing, and a maximum of half the spacing from a sidewall. Treat those figures as a reference point rather than a default layout: they are subject to the adopted edition, the detector&#8217;s listing and any local requirements, and a distributor shouldn&#8217;t apply them independently. Confirm any spacing with the qualified designer and the adopted code. That prescriptive spacing applies up to a stated ceiling height; the <a class=\"link\" href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-72\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">NFPA 72 quick reference<\/a> puts the smooth-ceiling limit for spot smoke at 40 ft. Above that, and on beamed, sloped or peaked ceilings, the layout has to change: beam depth relative to ceiling height decides whether the ceiling counts as smooth, and deep beams can require a detector in each pocket. The Fire Protection Research Foundation&#8217;s <a class=\"link\" href=\"https:\/\/www.nfpa.org\/-\/media\/Project\/Storefront\/Catalog\/Files\/Research\/Research-Foundation\/Reports\/Detection-and-signaling\/RFSmokeDetectorSpacinginHighCeilingSpacesII.pdf\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">study of smoke detector spacing in high ceiling spaces<\/a> is blunt about the underlying gap: NFPA 72 does not set spacing by ceiling height for smoke detection, and the research base for prescriptive high-ceiling rules is still limited. For a small business the practical consequence is simple \u2014 a high, beamed or sloped ceiling is a design question, not a catalogue question, and it should go to whoever signs the layout.<\/p>\n<p><strong>Kitchens and break rooms.<\/strong> Cooking is the classic nuisance source. The 2025 edition of NFPA 72 keeps smoke alarms and smoke detectors away from stationary or fixed cooking appliances \u2014 for smoke alarms, the distances in its smoke alarm provisions, and for smoke detectors, the corresponding detector provisions. The 2025 edition then adds provisions for listed nuisance-resistant devices \u2014 a 10 ft radius from a stationary or fixed cooking appliance, a 10 to 20 ft band along a horizontal flow path from it, and, where that would leave no viable location, an exception permitting a 6\u201310 ft radius for devices listed as nuisance-resistant to UL 217 or UL 268. Those figures are the 2025 edition&#8217;s provisions for listed devices, and whether they apply depends on the adopted edition and the jurisdiction. The <a class=\"link\" href=\"https:\/\/ulse.org\/news\/news-ul-smoke-alarm-standards-required-2025-nfpa-fire-alarm-and-signaling-code-what-it-means-your\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">UL Solutions summary of the 2025 change<\/a> explains what the listing actually tests: a broiling-hamburger nuisance test, with the device mounted 10 ft from an electric range. A listed device is not immune to cooking smoke; it is verified not to alarm below a defined obscuration level under that test. For a small caf\u00e9 or office kitchenette, the better answer is often to keep smoke detection out of the cooking zone and cover that area with heat detection instead.<\/p>\n<p><strong>Dusty areas.<\/strong> Dust is a documented nuisance cause in its own right \u2014 the <a class=\"link\" href=\"https:\/\/www.cfa.vic.gov.au\/fire-safety\/business-and-workplace-fire-safety\/commercial-fire-alarm-systems\/false-alarms-in-buildings\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">CFA&#8217;s guidance on false alarms in buildings<\/a> lists dust and dirt building up on sensors alongside fumes and steam. In a workshop, a stockroom handling cardboard, or a back-of-house area with ongoing trade work, the placement principle is to move the device out of the dust path rather than rely on cleaning to keep up with it. Where dust or another unsuitable condition is unavoidable, heat detection may suit the space better than a spot smoke detector, subject to the applicable design requirements.<\/p>\n<p><strong>The two offsets most often missed.<\/strong> Both are design considerations to check with the qualified designer or installer against the adopted code, not installation instructions. First, clearance from air supply diffusers: detectors shouldn&#8217;t sit in the direct airflow, and NFPA 72 Annex A carries guidance to keep them at least 36 inches from a supply diffuser or return opening. That 36-inch figure is Annex guidance unless the applicable adopted code makes it mandatory, so check what the authority having jurisdiction enforces. Second, wall mounting: where a detector is wall-mounted, the applicable NFPA provision gives a reference range of 4 to 12 inches between the top of the device and the ceiling, and what actually applies depends on the detector&#8217;s listing and the adopted code. Both offsets are easy to lose when a ceiling grid is installed after the detection layout was drawn.<\/p>\n<p>Matching detector type to the space is the point at which the <a class=\"link\" href=\"https:\/\/www.tyeefire.com\/product\/smoke-sensor\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">smoke sensor range<\/a> becomes relevant \u2014 the options differ because the spaces differ, not because one is universally better.<\/p>\n<h2 id=\"86abc38a-801b-481b-abe1-590c03daebad\" data-toc-id=\"86abc38a-801b-481b-abe1-590c03daebad\">Standalone vs. Interconnected, Addressable vs. Non-Addressable<\/h2>\n<p>No square-metre figure tells you when a small business should move from standalone alarms to a panel-based system. That decision comes from the adopted building code, the occupancy, and what the owner needs to know when something activates. What a distributor can do is explain what each option actually changes.<\/p>\n<p><strong>Standalone.<\/strong> A standalone smoke alarm protects the room it is in. It needs no panel, runs on battery or mains power with battery backup, and sounds locally. For a single-room unit, a small office suite, or a premises where a full system is not required, a battery stand-alone smoke detection alarm is a legitimate configuration rather than a compromise. The limitation is straightforward: an alarm in a back room isn&#8217;t necessarily heard at the front counter, and with no panel, nobody knows which device activated.<\/p>\n<p><strong>Interconnected.<\/strong> In a typical interconnected-alarm arrangement, devices are linked so that when one alarms, the others also sound \u2014 though the exact signal and notification behaviour depends on the product or system design and on applicable requirements. For a small business spread across a shop floor, a stockroom and an office, that is the difference between a warning that reaches staff and one that does not. Interconnection can be achieved within a standalone family or through a conventional or addressable system, depending on the products and the code requirement.<\/p>\n<p><strong>Addressable versus non-addressable (conventional).<\/strong> The distinction is what the panel tells you. A conventional panel reports a zone: the panel knows a circuit went into alarm but not which device on it. An addressable panel reports a point \u2014 a specific detector in a specific room \u2014 which is the key distinction from a zone-based conventional panel. Some compatible systems also track per-device sensitivity and dirty-chamber conditions, but treat that as a feature to confirm rather than a given. The <a class=\"link\" href=\"https:\/\/www.lifesafetycom.com\/addressable-vs-conventional-fire-alarm-systems\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">comparison published by Life Safety Com<\/a> notes that conventional is simpler and common in smaller buildings. The <a class=\"link\" href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-72\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">device table in the NFPA 72 quick reference<\/a> puts addressable cost higher per device but with fewer wire runs, and shows that on a short circuit with isolators only one segment drops, where a conventional zone fails entirely.<\/p>\n<p>For a small business, the question to ask the owner is not &#8220;how big is the building&#8221; but &#8220;when the panel goes off at 2 a.m., what do you need to know?&#8221; If the answer is &#8220;which room&#8221;, addressable earns its cost. If the answer is &#8220;that there is a fire somewhere and everyone is out&#8221;, conventional may be sufficient \u2014 subject to what the adopted code requires.<\/p>\n<p>Compatibility is worth stating plainly. Addressable devices speak the protocol of the panel family they were built for, so a head from one maker won&#8217;t work on another maker&#8217;s loop. Conventional devices are more forgiving but still need a listed-compatible pairing. When specifying an <a class=\"link\" href=\"https:\/\/www.tyeefire.com\/product\/addressable-smoke-detector\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">addressable smoke detector<\/a>, confirm the panel family first and the device second \u2014 the reverse order is how a good recommendation turns into a return.<\/p>\n<h2 id=\"4396e185-231d-4319-a93c-dccd9436f3d5\" data-toc-id=\"4396e185-231d-4319-a93c-dccd9436f3d5\">Wiring and Power: What Distributors Should Check<\/h2>\n<p>Wiring and power checks are where a plausible recommendation either holds up or comes back. The points below sit at check-point level \u2014 what to confirm before recommending a detector for a space, not how to install it. Installation and final commissioning belong with a qualified contractor working to the adopted code.<\/p>\n<p><strong>Power available at the intended location.<\/strong> Confirm whether the location has a mains circuit available or whether the device will be battery-only. A mains-powered device with battery backup behaves differently from a battery-only device during an outage, and the customer&#8217;s expectation should match the configuration sold.<\/p>\n<p><strong>Existing panel and its family.<\/strong> If the site already has a fire alarm panel, identify the make and family before proposing any device. Addressable devices are protocol-specific; a device that is technically excellent but incompatible with the installed loop isn&#8217;t a recommendation, it&#8217;s a return.<\/p>\n<p><strong>Circuit supervision.<\/strong> On a system-connected device, the circuit should be supervised in line with the applicable circuit class and the relevant supervision provisions for the system being discussed. Which conditions a supervised circuit reports, and how it reports them, depends on the circuit type and the system design \u2014 it is not the same for every circuit on every system. The <a class=\"link\" href=\"https:\/\/usmadesupply.com\/resources\/building-codes-standards\/emergency-life-safety\/nfpa-72\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">NFPA 72 quick reference<\/a> is a useful starting point for those provisions, but the adopted code and the system&#8217;s documentation govern. An unsupervised circuit can look healthy while providing no protection at all.<\/p>\n<p><strong>Battery backup expectations.<\/strong> Establish what the customer expects during a power failure and confirm the device or panel configuration meets it. Battery replacement intervals and load testing belong in the maintenance schedule, not in a verbal assurance at handover.<\/p>\n<p><strong>The adopted code edition and AHJ requirements.<\/strong> This is the check that is most often skipped. NFPA 72 is not mandatory unless a jurisdiction adopts and enforces it, and editions differ \u2014 the <a class=\"link\" href=\"https:\/\/ulse.org\/news\/news-ul-smoke-alarm-standards-required-2025-nfpa-fire-alarm-and-signaling-code-what-it-means-your\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">UL Solutions summary<\/a> notes that as of its writing some jurisdictions had adopted the 2022 edition while many states were still on 2019. Confirm the adopted edition and any local amendments with the AHJ rather than assuming the latest edition applies.<\/p>\n<p><strong>Air-handling and duct considerations.<\/strong> If the space has an air-handling system, duct detection may be required in addition to space detection, depending on the adopted mechanical code and the fire alarm code in force. Check the adopted mechanical code and the AHJ&#8217;s requirements for the supply and return thresholds that apply; those depend on the source document and jurisdiction, so this is a point to confirm rather than assume. Duct detector wiring connected to a fire alarm system is also subject to the supervision requirements of that system.<\/p>\n<p>Two of these checks \u2014 supervision and compatibility \u2014 account for most of the gap between a recommendation that works and one that comes back. Both are answerable before the order is placed.<\/p>\n<h2 id=\"4c20fd17-19fc-41be-9ca0-b6b251836125\" data-toc-id=\"4c20fd17-19fc-41be-9ca0-b6b251836125\">False Alarms: Common Causes and Checking Order<\/h2>\n<p>False alarms are usually a placement or maintenance problem in disguise. The causes fall into three groups, and the checking order below works through them from simplest to most involved.<\/p>\n<p><strong>Environmental causes.<\/strong> Dust and dirt building up on sensors, steam and fumes, and smoke from cooking or work processes are the recurring environmental triggers, per the <a class=\"link\" href=\"https:\/\/www.cfa.vic.gov.au\/fire-safety\/business-and-workplace-fire-safety\/commercial-fire-alarm-systems\/false-alarms-in-buildings\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">CFA&#8217;s cause list<\/a>. A detector sitting near a vent, a steamer or a loading bay will keep finding those sources no matter how many times it is reset.<\/p>\n<p><strong>System causes.<\/strong> Poor sensor placement near air vents or in high-traffic areas, ageing or poorly maintained equipment, battery issues, and a lack of regular cleaning and servicing all sit here. These are design and maintenance failures, not device failures.<\/p>\n<p><strong>Human causes.<\/strong> A lack of training \u2014 staff unfamiliar with the system triggering it accidentally \u2014 and vandalism, such as damage to break-glass points, complete the picture. Trades working on site without isolation are a well-documented variant: dust, heat and fumes from their work can activate detectors, which is why the CFA recommends isolating specific zones or circuits before work starts.<\/p>\n<p><strong>The checking order.<\/strong><\/p>\n<ol>\n<li><strong>Confirm whether there was an actual fire or a genuine sign of smoke or heat.<\/strong> Never reset first. Confirm the situation and follow the site&#8217;s emergency response procedure \u2014 if there was smoke or heat, the alarm did its job and the response is a fire response.<\/li>\n<li><strong>Check the log and identify the device or zone.<\/strong> A conventional panel gives you a zone; an addressable panel gives you a point. Either way, the log tells you whether this is a first occurrence or a pattern.<\/li>\n<li><strong>Inspect the device for dust and contamination, and clean it.<\/strong> Inspection and cleaning should be done by an appropriately qualified person following the manufacturer&#8217;s instructions. Contamination is one of the most common causes.<\/li>\n<li><strong>Check placement against nearby nuisance sources<\/strong> \u2014 cooking appliances, supply diffusers, steam, work processes. If the device sits inside a nuisance source&#8217;s reach, cleaning will only buy time.<\/li>\n<li><strong>Check battery and power.<\/strong> Distinguish an alarm activation from a trouble or fault indication: on a supervised system, a low battery or power fault is generally reported as a trouble or fault condition rather than an alarm. Identify the signal type from the device or panel before diagnosing it.<\/li>\n<li><strong>Check for trades or processes that should have been isolated.<\/strong> If work was underway, the isolation procedure is the finding, not the detector.<\/li>\n<li><strong>Escalate to the maintenance provider if the cause remains unexplained.<\/strong> An unexplained activation is a signal to investigate the system, not to reset and move on.<\/li>\n<\/ol>\n<p>The step that prevents recurrence is the one most often skipped: record the cause and the remedial action in the site log. Without that record, the same cause produces the same alarm next month. And the outcome to avoid is the one the <a class=\"link\" href=\"https:\/\/ulse.org\/news\/news-ul-smoke-alarm-standards-required-2025-nfpa-fire-alarm-and-signaling-code-what-it-means-your\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">UL Solutions article<\/a> highlights \u2014 a device disabled after a nuisance alarm cannot warn anyone when it matters.<\/p>\n<h2 id=\"509bab9d-be87-4333-a970-e6fdd395f6b9\" data-toc-id=\"509bab9d-be87-4333-a970-e6fdd395f6b9\">Installation and Maintenance Checklist<\/h2>\n<p>These items are short enough to work through on site and specific enough to hand to a customer. Each one maps back to a placement or false-alarm decision covered above.<\/p>\n<ul>\n<li>Confirm the adopted code edition and any local amendments with the AHJ before finalising the layout.<\/li>\n<li>Verify the detector type matches the space \u2014 smoke detection where appropriate, heat detection where dust or steam is unavoidable, subject to the applicable requirements.<\/li>\n<li>Check clearance from supply diffusers and from cooking appliances against the applicable adopted code and the listed device&#8217;s instructions. The common references are 36 inches from a supply diffuser or return opening (NFPA 72 Annex A guidance unless the adopted code makes it mandatory) and, for the 2025 NFPA 72 provisions on listed nuisance-resistant devices, a 10 ft radius and a 10\u201320 ft flow-path band, with a 6\u201310 ft exception where no viable location exists \u2014 subject to the adopted edition and jurisdiction.<\/li>\n<li>Confirm the power source and battery backup arrangement, and record what the customer should expect during an outage.<\/li>\n<li>Confirm interconnection where fitted, and have the installer verify that an alarm in one location is audible in the areas staff occupy.<\/li>\n<li>Confirm, with the qualified installer, that each device has been tested after installation and that the result is recorded against the device location.<\/li>\n<li>Set cleaning and testing intervals in the maintenance schedule, following the applicable code, the manufacturer&#8217;s instructions and the maintenance plan agreed with the qualified service provider.<\/li>\n<li>Keep a log book on site, accessible to staff and to the maintenance provider.<\/li>\n<li>Brief staff on isolation procedures for trades working on site.<\/li>\n<li>Review placement after any fit-out, partition change or layout change \u2014 a detector that was well placed before a refit may not be afterwards.<\/li>\n<\/ul>\n<p>The last item is the one that keeps the rest honest. Small business premises change more often than the detection layout does, and a review after each change is cheaper than discovering the mismatch during an alarm.<\/p>\n<h2 id=\"f247d7b9-444b-4228-aefd-ecea44a67b2d\" data-toc-id=\"f247d7b9-444b-4228-aefd-ecea44a67b2d\">Start With the Space, Then the Device<\/h2>\n<p>To come back to where this started: the small-business smoke detector problem is placement and false alarms, not price. A well-chosen detector in the wrong place tends to nuisance-alarm until someone disables it, while a modest detector in the right place often does its job well for a long time. The sequence that keeps both outcomes in check is the one this guide has followed \u2014 decide placement by space type first, then choose standalone or interconnected and addressable or non-addressable, then confirm wiring and power, then work the false-alarm checking order when something goes off, and keep the maintenance checklist live.<\/p>\n<p>TYEE makes smoke sensors, addressable detectors and standalone alarms across the configurations discussed here, and some of its products are UL-qualified \u2014 check the listing and its scope for the exact model you&#8217;re considering. The placement principles above apply regardless of whose devices are on the wall.<\/p>\n<p>If you&#8217;re working through a specific premises and want to discuss what a suitable smoke detector selection might look like for that space type, get in touch with <a class=\"link\" href=\"https:\/\/www.tyeefire.com\/\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TYEE Fire Protection<\/a> and your requirements, and we can talk them through with you.<\/p>","protected":false},"excerpt":{"rendered":"<p>A cheap smoke detector is not what prevents trouble in a small business. Problems come from unsuitable placement, from environmental [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5022,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[22,21],"tags":[],"class_list":["post-5021","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news","category-product-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/posts\/5021","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/comments?post=5021"}],"version-history":[{"count":0,"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/posts\/5021\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/media\/5022"}],"wp:attachment":[{"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/media?parent=5021"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/categories?post=5021"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tyeefire.com\/de\/wp-json\/wp\/v2\/tags?post=5021"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}